<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-21 18-45-23
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 60 dBuV SANDELS
Pilot RDS Phase Difference
5.5 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 67 kHz 18019 1,2764
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,1 dBr 3,48 dBr 4,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 67 kHz MIN: 12 kHz % above 76 kHz: 1,2764 Acquired: 2024/10/21 18.44.19 Total samples: 18019 Equivalent time: 0:15:00 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,1 dBr MIN: 2,1 dBr AVE: 3,48 dBr % above 12,2 dBr: 0,0 Last value: 2,3 dBr (2024/10/21 18.44.18) 18.30 18.32 18.34 18.36 18.38 18.40 18.42 18.44 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr]